76

A-Class Mark II

Step

Action

Displayed Message

Comment

G

Observe the calibration

result.

CALIBRATION COMPLETE

Calibration was successful.

If ‘Warning Low Backing’ is

displayed, calibration was
successful (for possible
messages see Section 5.1).

H

Press the ESC Key
repeatedly to exit menu

mode.

CALIBRATION COMPLETE

Followed by...

READY

When calibrating gap or
reflective media, press and hold

the FEED Key until at least one
label is output.


The printer is now ready for use.



5.2.2 Advanced Entry

Advanced Entry will override all previous calibration settings and should only be used
when Standard Calibration attempts fail. Ensure that the correct SENSOR TYPE is selected
(see Section 4.2.1) before staring this procedure.


Advanced Entry is an alternate calibration method for special-case media types, where sensor
readings are taken using different sampling algorithms and from a list of these readings the best

algorithm is selected for manual entry into the database. Follow the steps below to perform an
Advanced Entry Calibration:

Step

Action

Displayed Message

Comment

A

Turn ON the printer.

CANNOT CALIBRATE

-or-

UNCALIBRATED

Wait briefly for the printer to

initialize.

(Continued)