8 updating the firmware – Datamax-O'Neil A-Class Mark II Operator’s Manual User Manual
Page 108

98
A-Class Mark II
5.8 Updating the Firmware
Depending upon the firmware version, stored data on modules can be lost when
performing an update.
The printer’s application program (firmware) can be updated as versions become available. Identify
then download onto your computer’s hard drive the updated version of firmware for your model
printer from our web site at ftp.datamaxcorp.com
Follow the steps below to install the firmware:
If updating to version 11.021 or greater, the Boot Loader must be updated before
proceeding; see Section 5.9.
Firmware Update Procedure
Step Displayed Message
Action
Comment(s)
A READY
Using the DOS copy
command (where
‘filename’ is the program
to be loaded and ‘lpt1’ is
the selected interface
port), enter the
following:
copy filename lpt1
As an example, this would be entered
as:
copy A4212_1103A.zs lpt1
(Where ‘lpt1’ is the host computer’s
port; however, this selection can differ
to include a serial or other port, as the
printer is equipped.)
As data is received, the Comm
Indicator will appear.
B
UPGRADING
SOFTWARE
No action required.
The new application program is being
stored and verified.
C
A4212
11.03 01/01/2008
No action required.
The printer has automatically reset and
is displaying the new firmware version.
D
READY
No action required.
The new application is now running.
You may need to recalibrate the printer and reenter any custom settings. To verify the new
firmware version and current configuration, print a Configuration Label; see Section 4.3.2.
If the download was unsuccessful, the printer will perform a ‘warm reset’ and the original
firmware will remain operational. (If the reset fails to occur, cycle the power switch OFF
and ON.) A list of error messages and possible solutions is given below.