78

A-Class Mark II

Step

Action

Displayed Message

Comment

G

Press the UP Key,

incrementing the Gain
Number by one, and then

press the ENTER Key.
Record the sensor reading
as a Label Value in the

table.

Repeat this step for each
of the remaining Gain

Numbers.

GAIN TRAN

*01 (0 – 31)

- Or, for reflective media:

GAIN REFL

*01 (0 – 31)


Where ‘yyy’ represents the

current sensor reading.

Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252

01 250

02 248

… …

31 009

Step

Action

Displayed Message

Comment

H

Raise the printhead
assembly then proceed

according to the media
type:

Die-cut Media –
Remove a label or two
from the liner then

position the Eye Mark
over that area.

Notched Media –
Position the Eye Mark
over the center of a

notch.

Reflective Media –
Position the Eye Mark

over the center of a
face-down black mark.

GAIN TRAN

*31 (0 – 31)

- Or, for reflective media:

GAIN REFL

*31 (0 – 31)

See Section 3.2.