80

A-Class Mark II

Step

Action

Displayed Message

Comment

K

In the table, where both

the Label Value and TOF
Value are at least 20,

subtract the amounts and
record the result as a
Difference Value (see

below).

Identify the largest
Difference Value and then

the corresponding Gain
Number.

GAIN TRAN

*31 (0 - 31)

- Or, for reflective media:

GAIN REFL

*31 (0 – 31)

In this example, Gain

Number 18 is chosen

because, where both values
are at least twenty, it has

the highest Difference Value.

This Gain Number will be

used to resample the media.

Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252 248 4
01 250 245 5
02 248 234 14

… … … …

15 188 63 125
16 184 51 133
17 179 38 141
18

174

25

149

19 170 19 N/A

… … … …

31 132 14 N/A


Step

Action

Displayed Message

Comment

L

Scroll to the Gain Number

determined in the
previous step and then

press the ENTER Key.

GAIN TRAN

*18 (0 - 31)

- Or, for reflective media:

GAIN REFL

*18 (0 – 31)

After ENTER is pressed, an

asterisk (*) appears to denote
selection.

(Continued)