beautypg.com

Model lsb, Removal of mech. seal, Installation of a mech. seal – Xylem LSB User Manual

Page 95

background image

Installation, Operation and Maintenance Instruction

Model LSB

LSB 100-english

page 91

Revision 02

Artikel Nr. 771076129

Ausgabe 01/2010

3. Removal of mech. seal

For that purpose use the appropriate sectional drawing

and the enclosed data sheet of the mech. seal.

Remove and disassemble the pump acc. to the

Installation,

Operation

and

Maintenance

Instructions including chapter 8.6.

Remove fixing ring (527) (if existing) and rotating

part of the mech. seal (433) from shaft (210).

Refer to the enclosed data sheet of the mech.

seal, if set screws are to be loosened at the mech.

seal at first.

Remove stationary part of the mech. seal (433)

out of the casing cover (161).

Clean drilling for stationary seal rng (∅d

7

) in the

casing cover (161) and surface of shaft (210).

The reuse of mech. seals, which have already

been used for a longer time, can lead to leaking

at the seal faces after reinstallation. Therefore

the replacement of the mech. seal through a

new one is recommended. The dismounted

mechanical seal can be reconditioned by the

manufacturer and serve as a replacement

mech.seal.

4. Installation of a mech. seal

For that purpose use the sectional drawing and data

sheet of the mech. seal.

It is only allowed to install mech. seals, which

have a certificate of Conformity acc. the

Directive 94/9/EG.

On changing the mech. seal type resp. the

mech. seal manufacturer the data regarding

max. operating temperature of the pumped

medium and temperature class must be

checked again.

Pay attention to the utmost cleanness!

Especially the seal faces must be clean, dry and

undamaged. Don´t apply lubrication on the seal

faces of the mech. seal.

If a lubricant is provided with the replacement

mech. seal, you should use this.

Use mineral grease or oil only, if you are

completely sure that the elastomers of the

mech. seal are oil resistant. Use no silicone.

Use only lubricants when you are sure that

there can´t occur any dangerous reactions

between the pumpage and the lubricant

.

Make all required parts available, so that

assembly can be completed quickly. The

lubricants are only effective for a short time.

After that the axial movability and, thus, the

automatic adjustment of the elastomeres is lost.

Don´t push elastomers over sharp edges. If

necessary use mounting devices.

Press the stationary part of the mech. seal in the

casing cover (161). For this you can eventually

use a stamp with a soft surface. Unequal load can

lead to cracking of the seal face.

Don´t damage seal face!

Pay attention that the stationary ring is in solid

contact with the casing cover. The seal face must

be installed perpendicular to the shaft.

If a pin (560) is existing, be careful that it fits into

the slot of the mech. sealing, without touching the

mech. seal.

Push the rotating unit of the mech. seal on the

shaft (210).

Complete the face on the impeller side of the

mech. seal exactly with the shaft (measure l

1K

).

For mech. seals without own set screws the fixing

ring (527) serves as a stop.

Push mech. seals with bellows in such a way,

that the bellow is compressed and not stretched

(danger of tearing apart!).

Further mounting and installation of the pump

referring to the repair instructions.