Page 216: Application start, Configuration parameter values

Key Behavior
•
TAKE: this key is operational in ARM mode.
•
RECORD: the remote does not beep if the CAM key refers to an empty block.
•
RECORD: pressing this key while the current block is recording does not send any
command to the camera.
•
CLEAR: this key has no effect.
Cue points management
•
When a new ARM/REC command is issued on a block, all its cue points are cleared.
•
If the Last Cue command cannot access the desired TC-pre-roll, the player remains
on the current cue point.
•
If the Last Cue command refers to a TC that does not exist anymore, the player
jumps to the beginning of the current memory block.
•
Cue points can not be marked when working on several memory blocks.
Vision Research Camera
Application Start
At application start, the recording does not start automatically.
Configuration Parameter Values
•
Port = RS422 & Protocol = ASCII
•
Or Port = Ethernet & Protocol = TCP
•
The PGMSpeed parameter value 1000 is available.
Key Behavior
•
TAKE: this key is operational in any mode.
•
RECORD: the remote beeps if the CAM key refers to an empty block.
•
RECORD: pressing this key while the current block is recording clears all memory
blocks and starts recording on the first one.
•
CLEAR: press this key to delete the current memory block data.
206
9. Advanced Control Modes
EVS Broadcast Equipment S.A.
Issue 11.02.A July 2013