Toshiba M10 User Manual
Page 56
2 Troubleshooting Procedures
2.3 Power Supply Troubleshooting
2-10
Satellite Pro M10 Series Maintenance Manual (960-431)
1st Battery
Error code
Meaning
20h
Main battery overvoltage is detected. (Not supported)
21h
Main battery charge current is more than 6.05 A.
22h
Main battery discharge current is more than 0.5 A when there is no load.
23h
Main battery charge current is more than 4.3 A when DC IN direct charge
is off.
24h
Current sensing IC is not normal.
25h
Main battery charge current is more than 0.3A when the battery isn't
being charged.
2nd Battery
Error code
Meaning
30h
2nd battery overvoltage is detected. (Not supported)
31h
2nd battery charge current is more than 6.05 A.
32h
2nd battery discharge current is more than 0.5 A when there is no load.
33h
2nd battery charge current is more than 3.1 A when DC IN direct charge
is off.
34h
Current sensing IC is not normal.
35h
2nd battery charge current is more than 0.3A when the battery isn't being
charged.
S3V output
Error code
Meaning
40h
S3V voltage is under or equal to 3.14V when the computer is turned on
or off.
45h