beautypg.com

Toshiba M10 User Manual

Page 56

background image

2 Troubleshooting Procedures

2.3 Power Supply Troubleshooting

2-10

Satellite Pro M10 Series Maintenance Manual (960-431)

1st Battery

Error code

Meaning

20h

Main battery overvoltage is detected. (Not supported)

21h

Main battery charge current is more than 6.05 A.

22h

Main battery discharge current is more than 0.5 A when there is no load.

23h

Main battery charge current is more than 4.3 A when DC IN direct charge
is off.

24h

Current sensing IC is not normal.

25h

Main battery charge current is more than 0.3A when the battery isn't
being charged.

2nd Battery

Error code

Meaning

30h

2nd battery overvoltage is detected. (Not supported)

31h

2nd battery charge current is more than 6.05 A.

32h

2nd battery discharge current is more than 0.5 A when there is no load.

33h

2nd battery charge current is more than 3.1 A when DC IN direct charge
is off.

34h

Current sensing IC is not normal.

35h

2nd battery charge current is more than 0.3A when the battery isn't being
charged.

S3V output

Error code

Meaning

40h

S3V voltage is under or equal to 3.14V when the computer is turned on
or off.

45h