beautypg.com

Memory test – Toshiba M10 User Manual

Page 119

background image

3.5 Memory Test

3 Tests and Diagnostics

Satellite Pro M10 Series Maintenance Manual (960-431)

3-13

3.5 Memory

Test

To execute the Memory Test, select 2 from the DIAGNOSTIC TEST MENU, press Enter
and follow the directions on the screen. Move the highlight bar to the subtest you want to
execute and press Enter.

Subtest 01

Conventional memory

This subtest writes constant data to conventional memory (0 to 640 KB), then
reads the new data and compares the result with the original data.

Subtest 02

Protected Mode

NOTE: The CONFIG.SYS file must be configured without expanded memory manager
programs such as EMM386.EXE, EMM386.SYS or QEMM386.SYS. Also, the
HIMEM.SYS must be deleted from the CONFIG.SYS file.

This subtest writes constant data and address data to extended memory
(maximum address 100000h) then reads the new data and compares the result
with the original data.

The constant data is FFh, AAh, 55h, and 00h.