beautypg.com

Pitney Bowes DM550 User Manual

Page 171

background image

SV61436 Rev. B

10-11

DM500™ and DM550™ Digital Mailing System Operating Guide

Weighing Problems

Description

Possible Causes

Solution

Weight on internal scale

is erratic

Possible interference.

Remove everything from the scale and turn

off the power. Rezero the scale. To rezero

the scale, press the

Menu key, then select

Zero Scale.
Make sure when you place mail on the scale

you center it and check to make sure that it

is not touching another surface.

Weights on external

scale are erratic or the

scale does not return to

zero

For MP Series External Weighing

Platform scales:

The scale top cover my not be

seated properly on the scale

1. Remove the top cover and make sure

the 4 plastic grommets in the scale are

seated properly. The 4 plastic posts on

the top cover fit into these grommets.

2. If a grommet, or any part of a grommet,

is pushed below the surface of the metal

on the scale, reseat it until it appears as

shown here:

Grommet

pushed below

the surface

Grommet

seated properly

3. Check to make sure the bubble is cen-

tered in the circle as shown on the next

page. If not, and you have a flatblade

screwdriver, center the bubble by adjust-

ing the legs, otherwise go to step 4.