beautypg.com

System options menu, Able a-1, System – Paradyne 7112 User Manual

Page 78: Options, System options, Table a-1

background image

Configuration Option Tables

A-2

7112-A2-GB20-10

March 1998

Select . . .

To Configure the . . .

To Access the . . .

Telnet Port

Telnet Session Options

, Table A-7

Telnet user interface

SNMP

H

General SNMP Management
Options

, Table A-8

H

SNMP NMS Security Options

,

Table A-9

H

SNMP Traps Options

, Table A-10

Management support
through SNMP

System Options Menu

For System Options, refer to Table A-1. To access the System Options screen,
follow this menu selection sequence:

Main Menu

Configuration

Load Configuration From

System

Table A-1.

System Options

Self Test

Possible Settings: Enable, Disable
Default Setting: Enable

Controls whether or not the DSU/CSU performs a self-test at power-up and after reset.

Enable – Self-test will be performed at power-up and after a reset.

Disable – Self-test is disabled. The DSU/CSU will still perform a few basic tests (such
as memory and program checksum).

Test Timeout

Possible Settings: Enable, Disable
Default Setting: Enable

Allows user-initiated tests to end automatically. Recommend enabling when the unit is
managed remotely through the FDL to avoid the requirement to terminate the test
manually.

Enable – User-initiated loopback and pattern tests end when test duration is reached.

Disable – Tests can be terminated manually from the Network Tests screen. Refer to

Running Network Tests

in Chapter 7.

NOTE:

Tests commanded by the DTE or network-initiated tests are not affected by
this test timeout.

Test Duration (min)

Possible Settings: 1–120
Default Setting: 10

Number of minutes for a test to be active before automatically ending.

H

Test Duration (min) option appears when Test Timeout is enabled.

1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.