System options menu, Able a-1, System – Paradyne 7112 User Manual
Page 78: Options, System options, Table a-1
![background image](/manuals/170159/78/background.png)
Configuration Option Tables
A-2
7112-A2-GB20-10
March 1998
Select . . .
To Configure the . . .
To Access the . . .
Telnet Port
Telnet user interface
SNMP
H
General SNMP Management
Options
Table A-9
, Table A-10
Management support
through SNMP
System Options Menu
For System Options, refer to Table A-1. To access the System Options screen,
follow this menu selection sequence:
Main Menu
→
Configuration
→
Load Configuration From
→
System
Table A-1.
System Options
Self Test
Possible Settings: Enable, Disable
Default Setting: Enable
Controls whether or not the DSU/CSU performs a self-test at power-up and after reset.
Enable – Self-test will be performed at power-up and after a reset.
Disable – Self-test is disabled. The DSU/CSU will still perform a few basic tests (such
as memory and program checksum).
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows user-initiated tests to end automatically. Recommend enabling when the unit is
managed remotely through the FDL to avoid the requirement to terminate the test
manually.
Enable – User-initiated loopback and pattern tests end when test duration is reached.
Disable – Tests can be terminated manually from the Network Tests screen. Refer to
NOTE:
Tests commanded by the DTE or network-initiated tests are not affected by
this test timeout.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
H
Test Duration (min) option appears when Test Timeout is enabled.
1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.