beautypg.com

Running data port tests, Procedure – Paradyne 7112 User Manual

Page 65

background image

Testing

7-7

7112-A2-GB20-20

March 1998

"

Procedure

To run a Monitor QRSS test:

1. Position the cursor at the Start command next to Monitor QRSS on the

Network Tests screen.

2. If desired, use Ctrl-a to switch to the screen function key area and use the

virtual function key r or R (ResetMon) to clear the error counter to zero. Press
Ctrl-a to return the cursor to the Start command and press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stop

command and press Enter.

The Send and Monitor Pattern tests cannot be started when any loopback is
already active on the network interface.

Running Data Port Tests

To access the Data Port Tests screen, follow this menu selection sequence:

Main Menu

Test

Data Port Tests

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

main/test/data

PARADYNE

Device Name:

Model: 7112

DATA PORT TESTS

Test

Command

Status

Result

Local Loopbacks

Data Terminal Loopback:

Start

Inactive

0:00:00

Data Channel Loopback:

Start

Inactive

0:00:00

Remote Loopbacks

Send V.54 Loopback: Up

Send

Inactive

0:00:00

Send FT1 Loopback: Down

Send

Inactive

0:00:00

Pattern Tests

Send:

QRSS

Start

Inactive

0:00:00

Monitor:

QRSS

Stop

Active

99:08:48 – Errors 99999+

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Ctrl-a to access these functions, ESC for previous menu

MainMenu

Exit

ResetMon