Running data port tests, Procedure – Paradyne 7112 User Manual
Page 65
Testing
7-7
7112-A2-GB20-20
March 1998
"
Procedure
To run a Monitor QRSS test:
1. Position the cursor at the Start command next to Monitor QRSS on the
Network Tests screen.
2. If desired, use Ctrl-a to switch to the screen function key area and use the
virtual function key r or R (ResetMon) to clear the error counter to zero. Press
Ctrl-a to return the cursor to the Start command and press Enter.
The Start command is changed to Stop.
3. To manually stop the test, verify that the cursor is positioned at the Stop
command and press Enter.
The Send and Monitor Pattern tests cannot be started when any loopback is
already active on the network interface.
Running Data Port Tests
To access the Data Port Tests screen, follow this menu selection sequence:
Main Menu
→
Test
→
Data Port Tests
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
ООООООООООООООООООООООООО
main/test/data
PARADYNE
Device Name:
Model: 7112
DATA PORT TESTS
Test
Command
Status
Result
Local Loopbacks
Data Terminal Loopback:
Start
Inactive
0:00:00
Data Channel Loopback:
Start
Inactive
0:00:00
Remote Loopbacks
Send V.54 Loopback: Up
Send
Inactive
0:00:00
Send FT1 Loopback: Down
Send
Inactive
0:00:00
Pattern Tests
Send:
QRSS
Start
Inactive
0:00:00
Monitor:
QRSS
Stop
Active
99:08:48 – Errors 99999+
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu
MainMenu
Exit
ResetMon