Enterprise MIB Object
The following Paradyne Enterprise MIB Object is supported by the unit:
Device Configuration Variable (pdn-common 7)
The variable devConfigAreaCopy in the devConfigArea group is supported. This
variable allows the entire contents of one configuration area to be copied into
another configuration area. The unit only supports the following values.
Table C-17.
Device Configuration Variable
Object, OID, Access
Description
Setting/Contents
devConfigAreaCopy
1.3.6.1.4.1.1795.2.24.2.7.1.1
A “get” of this object will
always return noOp.
noOp(1)
1.3.6.1.4.1.1795.2.24.2.7.1.1
read-write
Copy from active area to
customer 1 area.
active-to-customer1(2)
Copy from active area to
customer 2 area.
active-to-customer2(3)
Copy from customer 1 area
to active area.
customer1-to-active(4)
Copy from customer 1 area
to customer 2 area.
customer1-to-
customer2(5)
Copy from customer 2 area
to active area.
customer2-to-active(6)
Copy from customer 2 area
to customer 1 area.
customer2-to-
customer1(7)
Copy from factory area to
active area. There is only one
factory area for the unit.
factory1-to-active(8)
Copy from factory area to
customer 1 area.
factory1-to-
customer1(9)
Copy from factory area to
customer 2 area.
factory1-to-
customer2(10)
Device Security, pdn-security (pdn-common 8)
Use the Device Security table to control the number of SNMP managers that may
access the unit, as well as the unit access level (read or read/write). Fully
supported by the unit.
Device Traps, pdn-traps (pdn-common 9)
Controls the SNMP managers to which the unit reports traps. Fully supported by
the unit.
Device Control, pdn-control (pdn-common 10)
Uses the devControlReset object to reset the unit. Fully supported by the unit.