beautypg.com

Paradyne 7112 User Manual

Page 137

background image

Standards Compliance for SNMP Traps

D-5

7112-A2-GB20-20

March 1998

The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-binding are different for each particular interface. Diagnostic tests are
only supported on the physical T1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:

Interface

enterpriseTestStart/Stop
Variable-Bindings

Possible Cause

Physical Sublayer

T1 network

H

ifIndex (RFC 1573)

H

ifAdminStatus
(RFC 1573)

H

ifOperStatus (RFC 1573)

H

i

fType (RFC 1573)

H

dsx1SendCode
(RFC1406)

H

enterpriseTest Start – Any one
of the following tests is active
on the interface:

– Remote Line Loopback

– Send QRSS pattern

H

enterpriseTest Stop – No
longer has any tests running
on the interface.

H

ifIndex (RFC 1573)

H

ifAdminStatus
(RFC 1573)

H

ifOperStatus (RFC 1573)

H

i

fType (RFC 1573)

H

dsx1LoopbackConfig
(RFC 1406)

H

enterpriseTest Start – Any one
of the following tests is active
on the interface:

– Line Loopback

– Payload Loopback

H

enterpriseTest Stop – No
longer has any tests running
on the interface.

H

ifIndex (RFC 1573)

H

ifAdminStatus
(RFC 1573)

H

ifOperStatus (RFC 1573)

H

i

fType (RFC 1573)

H

ifTestType (RFC 1573)

H

enterpriseTest Start – Any one
of the following tests is active
on the interface:

– Repeater Line Loopback

– Send 1-in-8 pattern

– All Monitor Pattern tests

H

enterpriseTest Stop – No
longer has any tests running
on the interface.

Synchronous User
Data Ports

H

ifIndex (RFC 1573)

H

ifAdminStatus
(RFC 1573)

H

ifOperStatus (RFC 1573)

H

i

fType (RFC 1573)

H

ifTestType (RFC 1573)

H

enterpriseTest Start – Any one
of the following tests is active
on the port:

– Local Loopback (DTE)

– Send 511 pattern

– Monitor 511 pattern

H

enterpriseTest Stop – No
longer has any tests running
on the port.