Paradyne 7112 User Manual
Page 137
Standards Compliance for SNMP Traps
D-5
7112-A2-GB20-20
March 1998
The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-binding are different for each particular interface. Diagnostic tests are
only supported on the physical T1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:
Interface
enterpriseTestStart/Stop
Variable-Bindings
Possible Cause
Physical Sublayer
T1 network
H
ifIndex (RFC 1573)
H
ifAdminStatus
(RFC 1573)
H
ifOperStatus (RFC 1573)
H
i
fType (RFC 1573)
H
dsx1SendCode
(RFC1406)
H
enterpriseTest Start – Any one
of the following tests is active
on the interface:
– Remote Line Loopback
– Send QRSS pattern
H
enterpriseTest Stop – No
longer has any tests running
on the interface.
H
ifIndex (RFC 1573)
H
ifAdminStatus
(RFC 1573)
H
ifOperStatus (RFC 1573)
H
i
fType (RFC 1573)
H
dsx1LoopbackConfig
(RFC 1406)
H
enterpriseTest Start – Any one
of the following tests is active
on the interface:
– Line Loopback
– Payload Loopback
H
enterpriseTest Stop – No
longer has any tests running
on the interface.
H
ifIndex (RFC 1573)
H
ifAdminStatus
(RFC 1573)
H
ifOperStatus (RFC 1573)
H
i
fType (RFC 1573)
H
ifTestType (RFC 1573)
H
enterpriseTest Start – Any one
of the following tests is active
on the interface:
– Repeater Line Loopback
– Send 1-in-8 pattern
– All Monitor Pattern tests
H
enterpriseTest Stop – No
longer has any tests running
on the interface.
Synchronous User
Data Ports
H
ifIndex (RFC 1573)
H
ifAdminStatus
(RFC 1573)
H
ifOperStatus (RFC 1573)
H
i
fType (RFC 1573)
H
ifTestType (RFC 1573)
H
enterpriseTest Start – Any one
of the following tests is active
on the port:
– Local Loopback (DTE)
– Send 511 pattern
– Monitor 511 pattern
H
enterpriseTest Stop – No
longer has any tests running
on the port.