Paradyne 7112 User Manual
Page 116
MIB Descriptions
C-14
7112-A2-GB20-10
March 1998
Table C-7.
DS1 Near End Group Configuration Table Objects (2 of 4)
Object, OID, Access
Setting/Contents
Description
dsx1LineCoding
(dsx1ConfigEntry 6 )
1.3.6.1.2.1.1.10.18.6.1.6
read-write
Corresponds to the network
line coding configuration
option for the network
interface on the DSU/CSU.
Supports the following
values:
H
dsx1B8ZS(2) – Indicates
B8ZS line coding.
H
dsx1AMI(5) – Indicates
AMI line coding.
dsx1SendCode
(dsx1ConfigEntry 7 )
1.3.6.1.2.1.1.10.18.6.1.7
read-write
Indicates the test
patterns/codes being sent
over the network interface.
Supports the following
values:
H
dsx1SendNoCode(1) –
specifies that the interface
is sending normal or
looped data. Setting the
interface to this value
stops an active “send
pattern” test on the
interface.
H
dsx1SendLineCode(2) –
specifies that the network
interface is sending a
Remote Loopback UP
code for 10 seconds.
H
dsx1SendResetCode(4) –
specifies that the network
interface is sending a
Remote Loopback DOWN
code for 10 seconds.
H
dsx1SendQRS(5) –
specifies that the network
interface is sending a
QRSS test pattern. The
pattern is sent until the test
is halted (i.e., setting to
dsx1SendNoCode).
H
dsx1SendOtherTestPatte
rn(8) – specifies that the
network interface is
sending a 1-in-8 test
pattern. The pattern is sent
until the test is halted (i.e.,
setting to
dsx1SendNoCode).
dsx1CircuitIdentifier
(dsx1ConfigEntry 8 )
1.3.6.1.2.1.1.10.18.6.1.8
read-write
Contains the transmission
vendor’s circuit identifier,
for the purpose of
facilitating troubleshooting.
Applies to the T1 network
interface only.
A string of 0 to
255 characters.