Table C-7.

DS1 Near End Group Configuration Table Objects (2 of 4)

Object, OID, Access

Setting/Contents

Description

dsx1LineCoding
(dsx1ConfigEntry 6 )

1.3.6.1.2.1.1.10.18.6.1.6
read-write

Corresponds to the network
line coding configuration
option for the network
interface on the DSU/CSU.

Supports the following
values:

H

dsx1B8ZS(2) – Indicates
B8ZS line coding.

H

dsx1AMI(5) – Indicates
AMI line coding.

dsx1SendCode
(dsx1ConfigEntry 7 )

1.3.6.1.2.1.1.10.18.6.1.7
read-write

Indicates the test
patterns/codes being sent
over the network interface.

Supports the following
values:

H

dsx1SendNoCode(1)
specifies that the interface
is sending normal or
looped data. Setting the
interface to this value
stops an active “send
pattern” test on the
interface.

H

dsx1SendLineCode(2)
specifies that the network
interface is sending a
Remote Loopback UP
code for 10 seconds.

H

dsx1SendResetCode(4)
specifies that the network
interface is sending a
Remote Loopback DOWN
code for 10 seconds.

H

dsx1SendQRS(5)
specifies that the network
interface is sending a
QRSS test pattern. The
pattern is sent until the test
is halted (i.e., setting to
dsx1SendNoCode).

H

dsx1SendOtherTestPatte
rn(8)
– specifies that the
network interface is
sending a 1-in-8 test
pattern. The pattern is sent
until the test is halted (i.e.,
setting to
dsx1SendNoCode).

dsx1CircuitIdentifier
(dsx1ConfigEntry 8 )

1.3.6.1.2.1.1.10.18.6.1.8
read-write

Contains the transmission
vendor’s circuit identifier,
for the purpose of
facilitating troubleshooting.

Applies to the T1 network
interface only.

A string of 0 to
255 characters.