Testing

7-8

7112-A2-GB20-20

March 1998

Data Terminal Loopback

Data Terminal Loopback (DTLB) loops the user data back to the DTE. This
loopback is located as closely as possible to the User Data Port (DTE) interface.

"

Procedure

To run a data terminal loopback:

1. Position the cursor at the Start command next to Data Terminal Loopback on

the Data Port Tests screen and press Enter.

The Start command is changed to Stop.

2. To manually stop the test, verify that the cursor is positioned at the Stop

command and press Enter.

97-15696

CSU

DSU

Network

Interface

DTLB

DTE

Port 1

ALL 1s

Data Terminal Loopback cannot be started when any other loopback is already
active on the data port.