Device messages – Paradyne 7112 User Manual
Page 72
![background image](/manuals/170159/72/background.png)
Messages and Troubleshooting
8-2
7112-A2-GB20-20
March 1998
To configure SNMP Traps, follow this menu selection sequence:
Main Menu
→
Configuration
→
Load Configuration From
→
SNMP
→
SNMP Traps
Refer to Table A-10,
Device Messages
in Table 8-1, listed in alphabetical order, may appear in the
messages area at the bottom of the ATI screens.
Table 8-1.
Device Messages (1 of 2)
Device Message
What Message Indicates
What To Do
Cannot Save – no
Login IDs with Access
Level 1
All of the login IDs being
saved have an access level
below Level 1.
Change the access level of at
least one Login ID to Level 1 so
that configuration changes can
be made. (Levels 2 and 3 cannot
make configuration changes.)
Save the Login IDs.
Command Complete
Action requested has
successfully completed.
No action needed.
Invalid Character (
x )
1
A nonprintable ASCII
character has been
entered.
Re-enter information using valid
characters.
Invalid – Data
Terminal (or Channel)
Initiated Loopback
Active
Network-initiated loopback
was in progress when
another selection was
made.
No action needed.
Invalid Password
Login is required and an
incorrect password was
entered; access is denied.
H
Try again.
H
Contact your system
administrator to verify your
password.
Invalid – [ Test ]
Already Active
The [test] was already in
progress when another
selection was made.
H
Allow test to continue.
H
Select another test.
H
Stop the test.
Invalid Test
Combination
A loopback or pattern test
was in progress when Start
was selected to start
another test, or was active
on the same or another
interface when Start was
selected.
H
Wait until other test ends and
message clears.
H
Abort all tests from the Test
menu screen.
H
Stop the test from the same
screen the test was started
from.
1
x is the character not being accepted.