Paradyne 7112 User Manual
Page 117
MIB Descriptions
C-15
7112-A2-GB20-20
March 1998
Table C-7.
DS1 Near End Group Configuration Table Objects (3 of 4)
Object, OID, Access
Setting/Contents
Description
dsx1LoopbackConfig
(dsx1ConfigEntry 9 )
1.3.6.1.2.1.1.10.18.6.1.9
read-write
This object specifies the
loopback state of the
network interface.
Applies to the T1 network
interface only.
Supports the following
values:
H
dsx1NoLoop(1) – The T1
interface is not in a
loopback state.
H
dsx1PayloadLoop(2) –
Specifies that a Payload
Loopback (PLB) is active
for the network interface.
H
dsx1LineLoop(3) –
Specifies that a Line
Loopback (LLB) is active
for the network interface.
H
dsx1OtherLoop(4) –
Specifies that an
unspecified type of
loopback is active for the
network interface.
dsx1LineStatus
(dsx1ConfigEntry 10 )
1.3.6.1.2.1.1.10.18.6.1.10
read-only
This object specifies the
line (alarm) status of the
network interface.
More than one value may be
active at a time.
Supports the following
values:
H
dsx1NoAlarm(1) – No
alarm present.
H
dsx1RcvFarEndLOF(2) –
A yellow alarm signal is
being received.
H
dsx1RcvAIS(8) – An
Alarm Indication Signal
(AIS) is being received.
H
dsx1LossOfFrame(32) –
An Out Of Frame condition
has persisted for more
than
2.5 seconds (i.e., Red
Alarm).
H
dsx1LossOfSignal(64) –
A Loss of Signal condition
has persisted for more
than
2.5 seconds (i.e., Red
Alarm).
H
dsx1LoopbackState(128)
– The near end of the
network interface is in a
loopback state.
H
dsx1Other Failure(4096)
– An Excessive Error Rate
(EER) has been detected
on the network interface.