beautypg.com

Health and status messages, On the network interface. refer to, Able 6-2 – Paradyne 7112 User Manual

Page 49

background image

Monitoring the DSU/CSU

6-7

7112-A2-GB20-20

March 1998

Health and Status Messages

The following messages appear in the first column of the System and Test Status
screen. The highest priority Health and Status message also appears on all ATI
screens on the bottom right.

Table 6-2.

Health and Status Messages (1 of 2)

Message

What Message Indicates

What To Do

Loss Of Signal

No signal is being received.
Local DSU/CSU network
problem. An LOS condition
(175 consecutive zeros) has
been detected on the network
interface.

1. Verify that the network cable is

securely attached at both ends.

2. Contact network provider.

Out of Frame

DSU/CSU is detecting an out
of frame condition. This
occurs when two out of four
frame synchronization bits are
in error.

1. Wait for the condition to clear.

2. Verify that the line framing format

configuration option matches the
setting of the network.

3. Contact network provider.

Alarm Indication
Signal

An Alarm Indication Signal
(unframed all ones signal) is
being received from the
network interface.

1. Check the status of the far-end

device(s).

2. Contact network provider.

Excessive Error
Rate

An Excessive Error Rate
condition has been detected
on the network interface. The
condition is cleared when the
error rate falls below the
threshold value.

1. Contact network provider.

Yellow Alarm

A Yellow Alarm signal is being
received from the network
interface.

1. Check the status of the far-end

device.

2. Contact network provider.

Primary Clock
Failed

The primary clock has failed.
Timing for the DSU/CSU is
provided by the internal clock.

1. Check the clock source

connector (DTE or Net).

2. If the primary clock was derived

from the network, contact the
network provider.

FDL Link Down

The FDL communication
between the local and remote
DSU/CSU is not working.

1. Verify that the remote unit has

FDL enabled.

2. Contact network provider if

problem persists.

Device Fail
yyyyyyyy

An internal error has been
detected by the operating
software.

yyyyyyyy indicates

the 8-digit hexadecimal failure
code.

1. Select the Clear function from the

Status screen.

2. Provide the 8-digit failure code

shown (

yyyyyyyy ) to your service

representative.