Table 10-1. UART Signal Descriptions (Sheet 1 of 2)

Name

Type

Description

RXD

Input

SERIAL INPUT: Serial data input to the receive shift register. In infrared
mode, it is connected to the infrared receiver input. This signal is present on
all three UARTs.

TXD

Output

SERIAL OUTPUT: Serial data output to the communications link-
peripheral, modem, or data set. The TXD signal is set to the logic 1 state
upon a Reset operation. It is connected to the output of the infrared
transmitter in infrared mode. This signal is present all three UARTs.

nCTS

Input

CLEAR TO SEND: When low, indicates that the modem or data set is ready
to exchange data. The nCTS signal is a modem status input and its
condition can be tested by reading bit 4 (CTS) of the Modem Status
Register. Bit 4 is the complement of the nCTS signal. Bit 0 (DCTS) of the
Modem Status Register (MSR) indicates whether the nCTS input has
changed state since the last time the Modem Status Register was read.
nCTS has no effect on the transmitter. This signal is present on the
FFUART and BTUART.
When the CTS bit of the MSR changes state and the Modem Status
interrupt is enabled, an interrupt is generated.

nDSR

Input

DATA SET READY: When low, indicates that the modem or data set is
ready to establish a communications link with a UART. The nDSR signal is
a Modem Status input and its condition can be tested by reading Bit 5
(DSR) of the MSR. Bit 5 is the complement of the nDSR signal. Bit 1
(DDSR) of the MSR indicates whether the nDSR input has changed state
since the MSR was last read. This signal is only present on the FFUART.
When the DSR bit of the MSR changes state, an interrupt is generated if the
Modem Status interrupt is enabled.

nDCD

Input

DATA CARRIER DETECT: When low, indicates that the data carrier has
been detected by the modem or data set. The nDCD signal is a modem
status input and its condition can be tested by reading Bit 7 (DCD) of the
MSR. Bit 7 is the complement of the nDCD signal. Bit 3 (DDCD) of the MSR
indicates whether the nDCD input has changed state since the previous
reading of the Modem Status Register. nDCD has no effect on the receiver.
This signal is only present on the FFUART.
When the DCD bit changes state and the Modem Status interrupt is
enabled, an interrupt is generated.