Partial label reading control, Decode negative image, Default – Datalogic QuickScan I QD2400 User Manual
Page 96
Enter/Exit Programming Mode
Scanning Features
86
QuickScan™ I QD24XX/QBT24XX/QM24XX
Partial Label Reading Control
Enable/Disable to ignore partial labels to be read within the boundary of the field of view.
IPPL00
Partial Label Reading Control = Disable
IPPL01
Partial Label Reading Control = Enable
Decode Negative Image
Enable/Disable the ability to decode a negative image for all symbologies. When this feature is
enabled, you will be unable to read normally-printed labels or programming labels in this man-
ual. Scan the “Disable” bar code below to return the scanner to its default for this feature. To set
decoding for only 2D codes, go to "
2D Normal/Inverse Symbol Control" on page 183
. For addi-
tional options, see the Aladdin configuration application.
NOTE
CAUTION
$P,CIPVR00,P(CR)
Decode Negative Image = Disable
DEFAULT
$P,CIPVR01,P(CR)
Decode Negative Image = Enable
When this feature is enabled, you will be unable to read other programming labels in this
manual.
Unlike some programming features and options, Decode Negative Image selections require
that you scan only one programming bar code label. DO NOT scan an ENTER/EXIT bar code
prior to scanning a Decode Negative Image bar code.