Standard 2 of 5 set length 1, Default – Datalogic QuickScan I QD2400 User Manual
Page 149
1D Symbologies
Enter/Exit Programming Mode
Product Reference Guide
139
Standard 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for
Standard 2 of 5 Length Control on page
. Length 1 is the minimum label length if in
Variable Length on page 138
Mode, or the first
fixed length if in
Mode. Length includes the bar code’s check and
data characters. The length can be set from 1 to 50 characters.
provides some examples for setting Length 1. See
if you want detailed
instructions on setting this feature.
Table 9. Standard 2 of 5 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Character
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CS2L1
Select Standard 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
08 = Length 1 is 8 Characters