beautypg.com

Standard 2 of 5 set length 1, Default – Datalogic QuickScan I QD2400 User Manual

Page 149

background image

1D Symbologies

Enter/Exit Programming Mode

Product Reference Guide

139

Standard 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for

Standard 2 of 5 Length Control on page

138

. Length 1 is the minimum label length if in

Variable Length on page 138

Mode, or the first

fixed length if in

Fixed Length on page 115

Mode. Length includes the bar code’s check and

data characters. The length can be set from 1 to 50 characters.

Table 9

provides some examples for setting Length 1. See

page 251

if you want detailed

instructions on setting this feature.

Table 9. Standard 2 of 5 Length 1 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

01 Character

07 Characters

15 Characters

50 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING

4

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘1’

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

5

Scan ENTER/EXIT PROGRAMMING MODE

$CS2L1

Select Standard 2 of 5 Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

08 = Length 1 is 8 Characters