Enter/Exit Programming Mode
Batch Features
220
QuickScan™ I QD24XX/QBT24XX/QM24XX
Copy Configuration to Base Station
Scan the following label to copy the current scanner configuration to the Base Station. Use this
method when the Auto Configuration Update feature is disabled and you want a one-time con-
figuration update to be performed on the Base Station.
Copy Configuration to Base Station
Cpycfg2Ba
NOTE
Do not scan an ENTER/EXIT PROGRAMMING MODE label with this bar code.
BATCH FEATURES
Batch Mode
This option specifies whether to store labels in the handheld while disconnected from the base.
Options are as follows:
• Disabled — The handheld will not store/batch labels.
• Automatic — The handheld will store labels to RAM when the handheld goes out of range
and is disconnected from the remote device.
• Manual — The handheld will always store labels to Flash memory. The user must manually
send the stored labels to the remote device using a special "batch send" label.
DEFAULT
$CBTBM00(CR)
Batch Mode = Disabled
$CBTBM01(CR)
Batch Mode = Automatic
$CBTBM02(CR)
Batch Mode = Manual