Codabar Start/Stop Character Set

This option specifies the format of transmitted Codabar start/stop characters

$CCBSC00(CR)

Codabar Check Character Set = ABCD/TN*E

$CCBSC01(CR)

Codabar Check Character Set = ABCD/ABCD

$CCBSC02(CR)

Codabar Check Character Set = abcd/tn*e

$CCBSC03(CR)

Codabar Check Character Set = abcd/abcd

DEFAULT

.

Codabar Start/Stop Character Match

When enabled, this option requires that start and stop characters match

DEFAULT

$CCBSM00(CR)

Codabar Start/Stop Character Match = Don’t Require Match

$CCBSM01(CR)

Codabar Start/Stop Character Match = Require Match

.