beautypg.com

Micro pdf417 length control, Micro pdf417 set length 1, Default – Datalogic QuickScan I QD2400 User Manual

Page 210

background image

Enter/Exit Programming Mode

200

QuickScan™ I QD24XX/QBT24XX/QM24XX

Micro PDF417 Length Control

This feature specifies either variable length decoding or fixed length decoding for this symbol-

ogy.

Variable Length:

For variable length decoding, a minimum and maximum length may be set.

Fixed Length:

For fixed length decoding, two different lengths may be set.

DEFAULT

$CMILC00(CR)

Micro PDF417 Length Control = Variable Length

$CMILC01(CR)

Micro PDF417 Length Control = Fixed Length

Micro PDF417 Set Length 1

Specifies one of the bar code lengths for

Micro PDF417 Length Control on page 200

. Length 1 is

the minimum label length if in

Variable Length

Mode, or the first fixed length if in Fixed Length

Mode. Length includes the bar code’s data characters only. Characters can be set from 0001 to

0366 characters (pad with zeroes) in increments of 01. Any value greater than 0366 will be

considered to be 0366.
See

page 251

for detailed instructions on setting this feature.

$CMIL1

Select Micro PDF417 Length 1 Setting

To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
characters in

Appendix D, Keypad

representing

your desired character(s). End by scanning the ENTER/
EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

0001 = Length 1 is 1 Character