Code 39
112
QuickScan™ I QD24XX/QBT24XX/QM24XX
CODE 39
The following options apply to the Code 39 symbology.
Code 39 Enable/Disable
$CC3EN00(CR)
Code 39 = Disable
$CC3EN01(CR)
Code 39 = Enable
DEFAULT
Code 39 Check Character Calculation
Enable this option to enables/disables calculation and verification of an optional Code 39 check
character. When disabled, any check character in the label is treated as a data character
$CC3CC00(CR)
Code 39 Check Character Calculation = Don’t Calculate
$CC3CC01(CR)
Code 39 Check Character Calculation =
Calculate Std Check
DEFAULT
$CC3CC02(CR)
Code 39 Check Character Calculation =
Calculate Mod 7 Check