beautypg.com

Symbologies, Set length, Mode. l – Datalogic QuickScan I QD2400 User Manual

Page 261: Ngth if in, Variable length on, Variable length, Th if in, Mode. leng, Mode, or, Ymbologies

background image

Symbologies

Product Reference Guide

251

Symbologies

Set Length

Length Control allows you to select either variable length decoding or fixed length decoding for

the specified symbology.

Variable Length:

For variable length decoding, a minimum and maximum length may be set.

Fixed Length:

For fixed length decoding, two different lengths may be set.

Set Length 1

This feature specifies one of the bar code lengths for Length Control. Length 1 is the minimum

label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length

includes the bar code’s data characters only.
The number of characters that can be set varies, depending on the symbology. Reference the

page for your selected symbology to see specific variables.

1. Determine the desired character length (varies depending on symbology). Pad the number

with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2. Go to the Set Length page for your selected symbology and scan the ENTER/EXIT PRO-

GRAMMING MODE bar code to enter Programming Mode.

3. Scan the bar code to SELECT LENGTH 1 SETTING for your selected symbology.
4. Scan the appropriate two digits from the keypad in

Appendix D, Keypad

, that represent the

length setting which was determined in the steps above. You will hear a two-beep indica-

tion after the last character.

NOTE

If you make a mistake before the last character, scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the beginning.

5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Prog Mode.

Set Length 2

This feature allows you to set one of the bar code lengths for the specified symbology. Length 2

is the maximum label length if in

Variable Length

Mode, or the second fixed length if in

Fixed

Length

Mode. See the page for the specific symbology for parameters.

The length that can be set varies depending on the symbology. A setting of 0 specifies to ignore

this length (only one fixed length).
Follow these instructions to set this feature:

1. Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad the

number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2. Go to the Set Length page for your selected symbology and scan the ENTER/EXIT PRO-

GRAMMING MODE bar code to enter Programming Mode.

3. Scan the bar code to SELECT LENGTH 2 SETTING for your selected symbology.