beautypg.com

I 2 of 5 check character transmission, I 2 of 5 length control, Default – Datalogic QuickScan I QD2400 User Manual

Page 143

background image

1D Symbologies

Enter/Exit Programming Mode

Product Reference Guide

133

I 2 of 5 Check Character Transmission

Enable this option to transmit the check character along with I 2 of 5 bar code data.

$CI2CT00(CR)

I 2 of 5 Check Character Transmission = Don’t Send

$CI2CT01(CR)

I 2 of 5 Check Character Transmission = Send

DEFAULT

I 2 of 5 Length Control

This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5

symbology.

Variable Length:

For variable length decoding, a minimum and maximum length may be set.

Fixed Length:

For fixed length decoding, two different lengths may be set.

DEFAULT

$CI2LC00(CR)

I 2 of 5 Length Control = Variable Length

$CI2LC01(CR)

I 2 of 5 Length Control = Fixed Length