RF Features

Product Reference Guide

271

STAR Radio Protocol Timeout

This parameter sets the valid wait time before transmission between the handheld reader and

Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (number of readers in the

same area). The selectable range for this feature is from 02 to 25 seconds.
Follow these instructions to set this feature:

1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 25 =

25, etc

3. Go to

page 234

and scanScan the ENTER/EXIT PROGRAMMING MODE barcode to enter Pro-

gramming Mode.

4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in

Appendix D, Keypad

, that represent the

duration which was determined in the steps above. You will hear a two-beep indication

after the last character.

NOTE

If you make a mistake before the last character, scan the CANCEL barcode to abort and not
save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See

Table 46

for some examples of how to set this feature.

Table 46. STAR Radio Protocol Timeout Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

2 Seconds

5 Seconds

10 Seconds

25 Seconds

2

Pad with leading zero(es)

02

05

10

25

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECTSTAR RADIO PROTOCOL TIMEOUT SETTING

5

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘2’

‘0’ and ‘5’

‘1’ and ‘0’

‘2’ AND ‘5’

6

Scan ENTER/EXIT PROGRAMMING MODE