beautypg.com

Ack nak timeout value – Datalogic QuickScan I QD2400 User Manual

Page 254

background image

References

244

QuickScan™ I QD24XX/QBT24XX/QM24XX

ACK NAK Timeout Value

This option specifies the amount of time the reader waits for an ACK character from the host

following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15

seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:

1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with

leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

3. Go to

page 38

and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-

ming Mode.

4. Scan the bar code: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in

Appendix D, Keypad

, that represent the

duration which was determined in the steps above. You will hear a two-beep indication

after the last character.

NOTE

If you make a mistake before the last character, scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See

Table 28

for some examples of how to set this feature.

Table 28. ACK NAK Timeout Value Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

200ms

1,000ms (1 sec.) 5200ms (5.2 sec.)

15,000ms (15 sec.)

2

Divide by 200

01

05

26

75

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT ACK NAK TIMEOUT VALUE SETTING

5

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘1’

‘0’ and ‘5’

‘2’ and ‘6’

‘7’ and ‘5’

6

Scan ENTER/EXIT PROGRAMMING MODE