I 2 of 5 set length 1, Default – Datalogic QuickScan I QD2400 User Manual
Page 144

Enter/Exit Programming Mode
Interleaved 2 of 5 (I 2 of 5)
134
QuickScan™ I QD24XX/QBT24XX/QM24XX
I 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for
I 2 of 5 Length Control on page 133
.
Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in
Fixed Length Mode. The length includes the bar code’s check and data characters. The length
can be set from 2 to 50 characters in increments of two.
provides some examples for setting Length 1. See
for detailed instructions on
setting this feature.
Table 7. I 2 of 5 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Characters
6 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to
yield two digits
02
06
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 of 5 LENGTH 1 SETTING
5
Scan Two Characters From
‘0’ and ‘2’
‘0’ and ‘6’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
$CI2L1
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
06 = Length 1 is 6 Characters