beautypg.com

Ack nak error handling, Indicate transmission failure, Ack nak e – Datalogic QuickScan I QD2400 User Manual

Page 49: Rror, Andling, Ndicate, Ransmission, Ailure, Default

background image

RS-232/USB-Com Interfaces

Enter/Exit Programming Mode

Product Reference Guide

39

ACK NAK Error Handling

This feature specifies the method the reader uses to handle receive errors detected while wait-

ing for an ACK character from the host.

DEFAULT

$CR2EH00(CR)

ACK NAK Error Handling = Ignore Errors Detected

$CR2EH01(CR)

ACK NAK Error Handling =

Process Error as Valid ACK Character

$CR2EH02(CR)

ACK NAK Error Handling = Process Error as

Valid NAK Character

Indicate Transmission Failure

This option enables/disables the reader’s ability to sound an error beep to indicate a transmis-

sion failure while in ACK/NAK mode

$CR2TF00(CR)

Indicate Transmission Failure = Disable Indication

$CR2TF01(CR)

Indicate Transmission Failure = Enable Indication

DEFAULT

.