Msi set length 1, Default – Datalogic QuickScan I QD2400 User Manual
Page 184
Enter/Exit Programming Mode
MSI
174
QuickScan™ I QD24XX/QBT24XX/QM24XX
MSI Set Length 1
This feature specifies one of the bar code lengths for
MSI Length Control on page 173
. Length 1
is the minimum label length if in
Mode, or the first fixed length if
in
Mode. Length includes the bar code’s data characters only. The
length can be set from 01 to 50 characters.
provides some examples for setting Length 1. See
for detailed instructions
on setting this feature.
Table 21. MSI Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Characters
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT MSI LENGTH 1 SETTING
4
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CMSL1
Select MSI Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save
the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT
01 = Length 1 is 1 Character