Enter/Exit Programming Mode

MSI

174

QuickScan™ I QD24XX/QBT24XX/QM24XX

MSI Set Length 1

This feature specifies one of the bar code lengths for

MSI Length Control on page 173

. Length 1

is the minimum label length if in

Variable Length on page 251

Mode, or the first fixed length if

in

Fixed Length on page 251

Mode. Length includes the bar code’s data characters only. The

length can be set from 01 to 50 characters.

Table 21

provides some examples for setting Length 1. See

page 251

for detailed instructions

on setting this feature.

Table 21. MSI Length 1 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

01 Characters

07 Characters

15 Characters

50 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT MSI LENGTH 1 SETTING

4

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘1’

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

5

Scan ENTER/EXIT PROGRAMMING MODE

$CMSL1

Select MSI Set Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save
the entry string. You can then start again at the beginning.

~

CANCEL

DEFAULT

01 = Length 1 is 1 Character