beautypg.com

Stand mode off time – Datalogic QuickScan I QD2400 User Manual

Page 273

background image

Scanning Features

Product Reference Guide

263

Stand Mode Off Time

This feature specifies the amount of time reader illumination stays off after pulling the trigger

when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms

to 16 seconds).
Follow these instructions to set this feature:

1. Determine the desired setting.
2. Pad the result with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 20 =

20, etc.

3. Go to

page 81

and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-

ming Mode.

4. Scan the bar code: Set Stand Mode Illuminator Off Time.
5. Scan the appropriate two digits from the keypad in

Appendix D, Keypad

, that represent the

setting which was determined in the steps above. You will hear a two-beep indication after

the last character.

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See

Table 38

for some examples of how to set this feature.

Table 38. Stand Mode Off Time

STEP

ACTION

EXAMPLES

1

Desired Setting

500 ms

1 Second

5.5 Seconds

16 Seconds

2

Pad leading zero

01

02

11

32

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT STAND MODE OFF TIME

5

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘1’

‘0’ and ‘2’

‘1’ and ‘1’

‘3’ and ‘2’

6