Aztec Code

Aztec Code Enable / Disable

Enables/disables the ability of the reader to decode Aztec Code labels.

DEFAULT

$CAZEN00(CR)

Aztec Code = Disable

$CAZEN01(CR)

Aztec Code = Enable

Aztec Code Length Control

This feature specifies either variable length decoding or fixed length decoding for this symbol-

ogy.

Variable Length:

For variable length decoding, a minimum and maximum length may be set.

Fixed Length:

For fixed length decoding, two different lengths may be set.

DEFAULT

$CAZLC00(CR)

Aztec Code Length Control = Variable Length

$CAZLC01(CR)