beautypg.com

Good read led duration, Default – Datalogic QuickScan I QD2400 User Manual

Page 86

background image

Enter/Exit Programming Mode

LED and Beeper Indicators

76

QuickScan™ I QD24XX/QBT24XX/QM24XX

Good Read LED Duration

This feature specifies the amount of time that the Good Read LED remains on following a good

read. The good read LED on time can be set within a range of 100 milliseconds to 25,500 milli-

seconds (0.1 to 25.5 seconds) in 100ms increments. A setting of 00 keeps the LED on until the

next trigger pull.
See

page 261

in “References” for detailed instructions and examples for setting this feature.

$CLAGL00(CR)

Good Read LED Duration Setting =
Keep LED on until next trigger pull

$CLAGL

Select Good Read LED Duration Setting

To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
acters in

Appendix D, Keypad

representing your

desired character(s). End by scanning the ENTER/EXIT
bar code again.

Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

003 = Good Read LED
stays on for 300 ms.

NOTE

Indicators are dimmed during sleep.