beautypg.com

Standard 2 of 5 check character transmission, Standard 2 of 5 length control, Default – Datalogic QuickScan I QD2400 User Manual

Page 148

background image

Enter/Exit Programming Mode

Standard 2 of 5

138

QuickScan™ I QD24XX/QBT24XX/QM24XX

Standard 2 of 5 Check Character Transmission

This feature enables/disables transmission of an optional Standard 2 of 5 check character.

$CS2CT00(CR)

Standard 2 of 5 Check Character Transmission = Don’t Send

$CS2CT01(CR)

Standard 2 of 5 Check Character Transmission = Send

DEFAULT

Standard 2 of 5 Length Control

This feature specifies either variable length decoding or fixed length decoding for the Standard

2 of 5 symbology.

Variable Length:

For variable length decoding, a minimum and maximum length may be set.

Fixed Length:

For fixed length decoding, two different lengths may be set.

DEFAULT

$CS2LC00(CR)

Standard 2 of 5 Length Control = Variable Length

$CS2LC01(CR)

Standard 2 of 5 Length Control = Fixed Length