1 outline of the data trace easy setup function, 2 data trace easy setup display – Yaskawa MP900 Series Machine Controller Programming Panel for Simple Operation User Manual
Page 124

Data Trace Easy Setup
6.1.1 Outline of the Data Trace Easy Setup Function
6-2
6
6.1 Outline and Display of the Data Trace Easy Setup Function
6.1.1 Outline of the Data Trace Easy Setup Function
There are many data items (e.g., position data and speed data items) that need to be traced.
The data trace easy setup function lists position and speed data items set for each axis, thus
making it possible to set trace data automatically by selecting the data to be traced.
The trigger signal for the trace data will be automatically allocated as well, which makes it
possible to omit setting the data trace definition.
This function will be enabled only if the check box to create a basic ladder program automatically in
the Setup Wizard 2: Definition Window is checked.
6.1.2 Data Trace Easy Setup Display
The Data Trace Easy Setup Dialog Box can be opened with the following procedure after
logging onto the Controller folder.
Opening through the File Manager
Select Definition Folder on the directory tree and double-click Data Trace Easy Set.
Note: The above window will appear when the user logs onto the Machine
Controller MP01 in GROUP910 and the Machine Controller MP01's
CPU1 in GROUP920.