beautypg.com

Default data example – Yaskawa MP900 Series Machine Controller Programming Panel for Simple Operation User Manual

Page 102

background image

4.3 Default Data

4-17

4

„

Default Data Example

The present register values will be displayed for each register.

Based on the above, the following description explains default data on the Motion Alarm
page.

1. The H01 drawing will not be generated and the alarm status of the H01 drawing will not

be displayed if the check box to create a basic ladder program automatically in the Setup
Wizard 2: Definition Window has not been checked.

In this case, the data on the parallel #1 alarm code will be displayed in number 1, fol-
lowed by data on the parallel #2 alarm code in number 2 and data on parallel #3 alarm
code in number 3.

2. The Motion Alarm page will by default display data on parallel #N alarm codes (N = 1,

2,…n).

If the check box for multitask in the Setup Wizard 2: Definition Window has been
checked (i.e., the number of tasks is 2 or more), the above data on parallel #N alarm
codes will not be displayed.

No.

Register

Number

DWG

Name

Display Type

Data

Symbol

Comment

1

DB000008

H01

BIN

OFF

Alarm exist

2

MW00040

HEX

0000

Process #1 alarm code

3

MW00041

HEX

0000

Process #2 alarm code

4

MW00042

HEX

0000

Process #3 alarm code

5

MW00043

HEX

0000

Process #4 alarm code

6

ILC022

HEX

00000000

A-axis alarm flag

7

ILC062

HEX

00000000

B-axis alarm flag

8

ILC0A2

HEX

00000000

C-axis alarm flag

9

ILC422

HEX

00000000

D-axis alarm flag

10

ILC462

HEX

00000000

E-axis alarm flag

11

ILC4A2

HEX

00000000

F-axis alarm flag

.
.

128