Yaskawa MP900 Series Machine Controller Programming Panel for Simple Operation User Manual
Page 115

Quick Reference
4.4.5 Editing Watch Page Data
4-30
4
• Data:
The number of the register where data is displayed or set.
• Set value: Input the register number.
2. DWG Name
• Data:
The name of the DWG where the register number exists.
• Set value: Input the DWG name.
If the D register is set for the register number, be sure that the D register is
set because the D register is a unique register of the DWG. Any other set
value will be ignored.
3. DSP Type
• Data:
Display format of register data.
• Set value: Select the display format of data from the drop-down list. The following
values can be selected.
4. Data (Register Data)
• Data:
Present register data
• Set value: Input the value according to the format set in DSP type.
The data set here will be reflected as register data.
5. Symbol
• Data:
The symbol (name) corresponding to the register number.
• Set value: Input the name (symbol) corresponding to the register data. The name
input here will be displayed above the register number on the drawing
specified by the DWG Name.
6. Comment
• Data:
Comment on data.
• Set value: Input the comment on the register data.
Up to 48 characters can be input.
Register Number Setting
Selection
Display/Value
Binary
Possible
BIN
ON/OFF display
Word
Possible
DEC
Decimal display
HEX
Hexadecimal display
BIN
Binary display
Long
Possible
LONG
Long (4-byte) display
HEX
Hexadecimal display
Float
Possible
FLOAT
Floating-point display