Appe – Yaskawa MP900 Series Ladder Programming Manual User Manual
Page 411

E.2 Precautions on Motion Parameters
E-3
Precautions
AppE
( 2 ) Do Not Use a Subscript to Reference a Motion Register in a Different Circuit
Motion registers on different circuits are not assigned to continuous memory location, just as is true for I/O registers
and motion registers.
When using a subscript, access registers within the range of motion registers for each circuit.
If the circuit numbers are the same, it is possible to access motion registers for different axes.
Circuit No.
Axis 1
Axis 2
...
Axis 16
1
OW8000 to OW807F
OW8080 to OW80FF
...
OW8780 to OW87FF
2
OW8800 to OW887F
OW8880 to OW88FF
...
OW8F80 to OW8FFF
3
OW9000 to OW907F
OW9080 to OW90FF
...
OW9780 to OW97FF
4
OW9800 to OW987F
OW9880 to OW98FF
...
OW9F80 to OW9FFF
5
OWA000 to OWA07F
OWA080 to OWA0FF
...
OWA780 to OWA7FF
6
OWA800 to OWA87F
OWA880 to OWA8FF
...
OWAF80 to OWAFFF
7
OWB000 to OWB07F
OWB080 to OWB0FF
...
OWB780 to OWB7FF
8
OWB800 to OWB87F
OWB880 to OWB8FF
...
OWBF80 to OWBFFF
9
OWC000 to OWC07F
OWC080 to OWC0FF
...
OWC780 to OWC7FF
10
OWC800 to OWC87F
OWC880 to OWC8FF
...
OWCF80 to OWCFFF
11
OWD000 to OWD07F
OWD080 to OWD0FF
...
OWD780 to OWD7FF
12
OWD800 to OWD87F
OWD880 to OWD8FF
...
OWDF80 to OWDFFF
13
OWE000 to OWE07F
OWE080 to OWE0FF
...
OWE780 to OWE7FF
14
OWE800 to OWE87F
OWE880 to OWE8FF
...
OWEF80 to OWEFFF
15
OWF000 to OWF07F
OWF080 to OWF0FF
...
OWF780 to OWF7FF
16
OWF800 to OWF87F
OWF880 to OWF8FF
...
OWFF80 to OWFFFF
Circuit 1
Example:
I = 1;
OW87FFi = 0;
Not accessible.
Accessible.
Axis 1 (IW8000 to IW807F and OW8000 to OW807F)
Axis 2 (IW8080 to IW80FF and OW8080 to OW80FF)
Axis 16 (IW8780 to IW87FF and OW8780 to OW87FF)
Example:
I = 1;
OW807Fi = 0;
Circuit 2
Axis 1 (IW8800 to IW887F and OW8800 to OW887F)
Axis 2 (IW8880 to IW88FF and OW8880 to OW88FF)
Axis 16 (IW8F80 to IW8FFF and OW8F80 to OW8FFF)