Mstr transaction #2 – Yaskawa VS-616G5 Modbus Plus Communication Card User Manual
Page 75

Examples 9-31
MSTR Transaction #2
The Control Block registers for the second MSTR must be loaded with the following data before
the MSTR block is executed. This MSTR reads the drive status from drive #3.
CONTROL BLOCK
Register
Number
Register
Description
Register
Data
Data
Description
40710
Operation Code
0002h
0002h = Read from Multiple Registers
40711
Network Error Code
0000h
The error code returned by Modbus Plus
communications
40712
Number of Registers
0010h
Read from 16 consecutive registers
40713
Data Register Code
F000h
F000h = Drive Status Signals
40714
Routing 1
0003h
Modbus Plus node address of the drive = 0003h
40715
Routing 2
0001h
End of routing path = 0001h (Modbus Plus
requirement)
40716
Routing 3
0000h
This routing register is not used, must be set to 0
40717
Routing 4
0000h
This routing register is not used, must be set to 0
40718
Routing 5
0000h
This routing register is not used, must be set to 0
The Data Block registers for the second MSTR will be filled with the following data after the MSTR
is completed.
DATA BLOCK
Register
Number
Register
Description
Register
Data
Data
Description
40720
Drive Status Signals
READ
RUN/STOP, FWD/REV, Drive Ready, etc.
40721
Motor Speed
READ
Motor Speed
40722
Torque Reference
READ
Torque Reference
40723
not used
n/a
n/a
40724
Speed Reference
READ
Frequency command to drive
40725
Output Frequency
READ
(0.1 Hz) Frequency at the drive
40726
Output Current
READ
Current at the output
40727
Analog Input
READ
Control Circuit Term 14 Input Volatge
40728
DC Bus Voltage
READ
(1.0 V) DC Bus voltage
40729
Fault Content 1
READ
Overcurrent, Overvoltage,
40730
Fault Content 2
READ
Drive Overload,
40731
Fault Content 3
READ
etc.
40732
Analog Input
READ
Control Circuit Term 16 Input Voltage
40733
Digital Input
READ
Input Terminal Status
40734
Analog Input
READ
Control Circuit Term 13 Input Voltage
40735
not used
n/a
n/a