Yaskawa VS-616G5 Modbus Plus Communication Card User Manual
Page 104

Data Registers
A-24
Drive Parameter Registers (Read/Write) – continued
REGISTER PARAMETER
PARAMETER
PARAMETER
LIMITS / DESCRIPTION
INITIAL
(in hex)
FUNCTION
SETTING
VALUE
300h
E1-01
Input Voltage Setting
155 to 255V (230V unit)
310 to 510V (460V unit)
230
460
301h
E1-02
Motor Selection
0
Std Fan Cooled Gen. Purpose Mtr
(TEFC)
0
1
Blower Cooled Motor
(TENV or TEBC)
302h
E1-03
V/f Pattern Selection
0 to E
15 preset V/f patterns
F
Custom Pattern
(using E1-04 to E1-10)
F
303h
E1-04
Maximum Output Frequency
40.0 to 400.0 Hz
60.0
304h
E1-05
Maximum Voltage
0.0 to 255.0V (230V unit)
0.0 to 510.0V (460V unit)
230.0
460.0
305h
E1-06
Base Frequency
0.0 to 400.0 Hz
60.0
306h
E1-07
Mid. Output Frequency A
0.0 to 400.0 Hz
(1)
307h
E1-08
Mid Output Voltage A
0.0 to 255.0V (230V unit)
0.0 to 510.0V (460V unit)
(1)
308h
E1-09
Min. Output Frequency
0.0 to 400.0 Hz
(1)
309h
E1-10
Min. Output Voltage
0.0 to 255.0V (230V unit)
0.0 to 510.0V (460V unit)
(1)
30Ah
E1-11
Mid Frequency B
0.0 to 400.0 Hz
0.0
30Bh
E1-12
Mid Voltage B
0.0 to 255.0 VAC
0.0
30Ch
E1-13
Base Voltage
0.0 to 255.0 VAC
0.0
30Dh
Reserved
Notes (for this page only):
(1) Initial Value differs depending on the control method (A1-02).
(2) Initial Value differs depending on drive capacity.