Modbus plus communication connection – Yaskawa VS-616G5 Modbus Plus Communication Card User Manual
Page 17

Installation of the MB+ Board 3-7
Modbus Plus Communication Connection
Communication between a VS-616G5 drive and the MB+ network requires a physical connection
from your drive to the MB+ network. Connect your network communication cable into P1 (9-pin
“D” shell) on the MB+ board. Modicon offers cables and connectors for the MB+ network.
Modicon Modbus Plus Wiring:
The recommended cable for MB+ network connections is Belden 9841. This cable consists of:
??
One twisted signal pair: blue/white
??
Drain wire: bare
??
Overall aluminized mylar shield
This cable is available from Modicon as the following part numbers:
??
97-9841-100
MBPlus 100 Foot Reel
??
97-9841-500
MBPlus 500 Foot Reel
??
97-9841-01K
MBPlus 1000 Foot Reel
Two types of connectors are available from Modicon for connecting devices to the network. Each
in-line drop requires an in-line connector. The two drops at the ends of the Modbus Plus network
cable each require a terminating connector. When the terminating connectors are installed on the
two extreme ends of the cable, no other termination is required.
??
AS-MBKT-085
MBPlus In-line Connector (quantity 1)
??
AS-MBKT-185
MBPlus Terminating Connector (quantity 1)
??
AS-MBPL-001
MBPlus Connector Assembly Tool
Route the Modbus Plus cable out of the bottom of the drive enclosure. Select a cable routing
method to protect the cable from physical damage and potential electrical interference sources.
Note: Avoid sources of electrical interference capable of inducing noise into the cable.
If a cable must cross power wiring, it must cross only at a right angle.