Data Registers

A-33

Drive Parameter Registers (Read/Write) – continued

REGISTER PARAMETER

PARAMETER

PARAMETER

LIMITS / DESCRIPTION

INITIAL

(in hex)

FUNCTION

SETTING

VALUE

500h

o1-01

Monitor Selection

4 to 25, 28, 32, 33

6

501h

o1-02

Monitor Selection after Power-up

1

Frequency Reference

2

Output Frequency

1

3

Output Current

4

Selected Monitor

502h

o1-03

Digital Operator Display Scaling

0 to 39999

0

503h

o1-04

Digital Operator Display Units

0

Hz

0

1

RPM

504h

o1-05

Parameter / Address Display

0

Parameter Number

0

Selection

1

Modbus Address

505h

o2-01

LOCAL / REMOTE Key

0

Disabled

1

Selection

1

Enabled

506h

o2-02

STOP Key Function during

0

Disabled

1

Remote Run

1

Enabled

507h

o2-03

User Parameter Default Value

0

Disabled

1

Set Default

0

2

Clear all

508h

o2-04

kVA Selection (Drive Model No.)

0 to FFh

(1)

509h

o2-05

Digital Operator

0

Drive accepts freq. after ENTER key

0

“Motor Operated Pot”

1

Drive accepts freq. immediately

50Ah

o2-06

Operation Selection when Digital

0

Disabled (operation continues)

0

Operator is disconnected

1

Enabled (motor coast to stop; fault)

50Bh

o2-07

Elapsed Operating Hour Timer Set

0 to 65535 hours

-

50Ch

o2-08

Elapsed Operating Hour Timer

0

Timer active when power applied to drive

0

Selection

1

Timer active when drive is in run mode

50Dh

o2-09

Initialization Mode Selection

0

Japanese Spec.

1

American Spec.

1

2

European Spec.

Notes (for this page only):

(1) Not initialized. Initial value differs depending on the drive capacity.