Data Registers
A-27
Drive Parameter Registers (Read/Write) – continued
REGISTER PARAMETER
PARAMETER
PARAMETER
LIMITS / DESCRIPTION
INITIAL
(in hex)
FUNCTION
SETTING
VALUE
38Dh
F2-01
AI-14 Bi-polar or Uni-polar Input
0
3-channel Individual
0
Selection
1
3-channel Addition
38Eh
F3-01
DI-16 Digital Input Option
0
BCD 1%
1
BCD 0.1%
2
BCD 0.01%
3
BCD 1 Hz
0
4
BCD 0.1 Hz
5
BCD 0.01 Hz
6
BCD (5DG) 0.01 Hz
7
Binary
38Fh
F4-01
AO-08/AO-12 Channel 1 Monitor Select.
1 to 33
2
390h
F4-02
AO-08/AO-12 Channel 1 Gain
0.00 to 2.50
1.00
391h
F4-03
AO-08/AO-12 Channel 2 Monitor Select.
1 to 33
3
392h
F4-04
AO-08/AO-12 Channel 2 Gain
0.00 to 2.50
0.50
393h
F5-01
DO-02 Channel 1 Output Selection
0 to 20h, 30h, 37h
0
394h
F5-02
DO-02 Channel 2 Output Selection
0 to 20h, 30h, 37h
1
395h
F6-01
DO-08 Output Mode Selection
0
8-channel Individual
0
1
Binary Output
396h
F7-01
PO-36F Frequency Multiple
0
1 x Output Frequency
Selection
1
6 x Output Frequency
2
10 x Output Frequency
1
3
12 x Output Frequency
4
36 x Output Frequency
398h
Reserved
399h
F9-01
setting
0=normally open 1=normally closed
0
39Ah
F9-02
detection
0=always detected 1=during run
0
39Bh
F9-03
fault action
0
ramp to stop
1
1
coast to stop
2
fast-stop
3
alarm only
39Ch
F9-13
trace sample
trace sample time
0