Configuration procedure, Setting the web idle timeout timer – H3C Technologies H3C SecBlade LB Cards User Manual
Page 74

64
Configuration procedure
To change the system time:
Step Command
Remarks
1.
Set the system time and date. clock datetime time date
Optional.
Available in user view.
2.
Enter system view.
system-view
N/A
3.
Set the time zone.
clock timezone zone-name { add |
minus } zone-offset
Optional.
Coordinated UTC time zone by
default.
4.
Set a daylight saving time
scheme.
•
Set a non-recurring scheme:
clock summer-time zone-name
one-off start-time start-date
end-time end-date add-time
•
Set a recurring scheme:
clock summer-time zone-name
repeating start-time start-date
end-time end-date add-time
Optional.
Use either command.
By default, daylight saving time is
disabled, and the UTC time zone
applies.
Setting the Web idle timeout timer
Setting the Web idle timeout timer in the Web interface
Perform this task to set the idle timeout period for logged-in users. The system logs out a user that is idle
within the specified period.
To set Web idle timeout:
1.
Select System > Device Management > Web Management from the navigation tree to enter the
page shown in
.
2.
Enter the idle timeout.
3.
Click Apply.
Figure 45 Web management