beautypg.com

Configuration guidelines – H3C Technologies H3C SecBlade LB Cards User Manual

Page 149

background image

139

[LBA-GigabitEthernet0/1] display ntp-service status

Clock status: synchronized

Clock stratum: 4

Reference clock ID: 3.0.1.31

Nominal frequency: 64.0000 Hz

Actual frequency: 64.0000 Hz

Clock precision: 2^7

Clock offset: 0.0000 ms

Root delay: 31.00 ms

Root dispersion: 8.31 ms

Peer dispersion: 34.30 ms

Reference time: 16:01:51.713 UTC Sep 19 2005 (C6D95F6F.B6872B02)

Configuration guidelines

A device can act as a server to synchronize the clock of other devices only after its clock has been

synchronized. If the clock of a server has a stratum level higher than or equal to that of a client's clock,
the client does not synchronize to the server.
The synchronization process takes a period of time. Therefore, the clock status might be unsynchronized

after your configuration in the Web interface. In this case, you can refresh the page to view the clock

status later on.
If the system time of the NTP server is ahead of the system time of the device, and the difference between

them exceeds the Web idle time specified on the device, all online Web users are logged out because

of timeout.