Resetting the system of the lb module – H3C Technologies H3C SecBlade LB Cards User Manual
Page 60

50
Logging in to the LB module from the network
device
Logging in to the LB module from the network device
Use the following command to log in to the LB module. After login, the terminal screen displays the CLI
of the LB module. To return to the CLI on the device, press Ctrl+K.
To log in to the LB module from the network device, execute one of the following commands in user view
as appropriate:
Task Command
Log in to the OAP system from the device.
•
In standalone mode:
oap connect slot slot-number
•
In IRF mode:
oap connect chassis chassis-number slot slot-number
Monitoring and managing the LB module on the
network device
Resetting the system of the LB module
CAUTION:
Resetting the LB module might cause data loss and service interruption. Before resetting the LB module,
save the configurations of the LB module operating system and shut down the LB module operating system
to avoid service interruption and data loss.
If the operating system of the LB module works abnormally (for example, the system does not respond),
you can reset the system with the following command.
The LB module has an independent CPU; therefore, the network device can still recognize and control the
LB module after you reset the system of LB module.
To reset the system of the LB module, execute one of the following commands in user view as appropriate:
Task Command
Reset the LB module.
•
In standalone mode:
oap reboot slot slot-number
•
In IRF mode:
oap reboot chassis chassis-number slot slot-number