Verifying the configuration – H3C Technologies H3C S12500 Series Switches User Manual
Page 432

416
[SwitchB] interface vlan-interface 102
[SwitchB-Vlan-interface102] multicast ipv6 boundary scope 4
[SwitchB-Vlan-interface102] quit
[SwitchB] interface vlan-interface 103
[SwitchB-Vlan-interface103] multicast ipv6 boundary scope 4
[SwitchB-Vlan-interface103] quit
# On Switch C, configure VLAN-interface 103 and VLAN-interface 106 to be the boundary of
admin-scoped zone 2.
[SwitchC] interface vlan-interface 103
[SwitchC-Vlan-interface103] multicast ipv6 boundary scope 4
[SwitchC-Vlan-interface103] quit
[SwitchC] interface vlan-interface 106
[SwitchC-Vlan-interface106] multicast ipv6 boundary scope 4
[SwitchC-Vlan-interface106] quit
# On Switch D, configure VLAN-interface 107 to be the boundary of admin-scoped zone 2.
[SwitchD] interface vlan-interface 107
[SwitchD-Vlan-interface107] multicast ipv6 boundary scope 4
[SwitchD-Vlan-interface107] quit
5.
Configure C-BSRs and C-RPs:
# On Switch B, configure the service scope of RP advertisements and configure VLAN-interface
101 as a C-BSR and C-RP of admin-scoped zone 1.
[SwitchB] pim ipv6
[SwitchB-pim6] c-bsr scope 4
[SwitchB-pim6] c-bsr 1002::2
[SwitchB-pim6] c-rp 1002::2 scope 4
[SwitchB-pim6] quit
# On Switch D, configure the service scope of RP advertisements and configure VLAN-interface
104 as a C-BSR and C-RP of admin-scoped zone 2.
[SwitchD] pim ipv6
[SwitchD-pim6] c-bsr scope 4
[SwitchD-pim6] c-bsr 3002::2
[SwitchD-pim6] c-rp 3002::2 scope 4
[SwitchD-pim6] quit
# On Switch F, configure VLAN-interface 109 as a C-BSR and C-RP in the global-scoped zone.
[SwitchF] pim ipv6
[SwitchF-pim6] c-bsr scope global
[SwitchF-pim6] c-bsr 8001::1
[SwitchF-pim6] c-rp 8001::1
[SwitchF-pim6] quit
Verifying the configuration
To view the BSR election information and the C-RP information on a switch, use the display pim
ipv6 bsr-info command. For example:
# Display the BSR information and the locally configured C-RP information on Switch B.