Solution – H3C Technologies H3C S12500 Series Switches User Manual
Page 233

217
Solution
1.
Use the display ip routing-table command to verify that the unicast route between the devices is
correct.
2.
Check that a unicast route is available between the two devices that will become MSDP peer to
each other.
3.
Verify the configuration of the originating-rp command. In the Anycast RP application environment,
be sure to use the originating-rp command to configure the RP address in the SA messages, which
must be the local interface address.
4.
Verify that the C-BSR address is different from the Anycast RP address.
This manual is related to the following products: